The popularity of RFID hotel door locks has always been relatively high. RFID hotel door locks are installed in many hotels, which makes maintenance and management much easier and greatly enhances the hotel’s style. Most hotels now use smart door locks.
I. Why Should Hotel Door Locks Be Maintained?
Compared with traditional door locks, hotel RFID door locks have many advantages, but the maintenance of RFID hotel door locks is more sophisticated than traditional door locks. Hardware and machinery belong to the category of smart hotel RFID locks, and the general warranty period is two years.
At present, the technology is relatively mature, and crashes rarely occur. Hotel smart door locks must be more intelligent, but if the maintenance of hotel RFID door locks can be done well, the service life of RFID hotel door locks will be prolonged. High-quality hotel card lock products and a stable hotel door lock system will make the product life longer, reduce maintenance costs, save several labor costs, and maintain the overall image of the hotel. So how to maintain the hotel door locks?
II. Hotel door lock repair-main components.
The main components of smart RFID hotel door locks generally include lock panels, mechanical lock cylinders, lock tenons, motherboards, battery packs, etc.
1) Hotel door lock panel maintenance
The hotel radio frequency card lock panel includes a front panel and a rear panel. The hotel’s door lock handles often break down here. Butter should be added to the handle spring of the door lock every year. If there is lubricant in the transmission part of the lock body, the handle will not be stuck.
The transmission is stable and the service life can be prolonged. At the same time, check whether the panel fastening screws are loose and make sure they are tight.
2) Maintenance of the mechanical cylinder of the hotel door lock
During the use of hotel key card locks, mechanical lock cylinders are rarely used. Guests in ordinary rooms use the room key card to open the door. It has been needed as a backup method to open the door from time to time. In special circumstances, this key is used to open the door.
It is recommended to perform mechanical lock core maintenance every year or when the key is not smoothly inserted and removed. You can put a small amount of graphite powder or pencil powder into the lock cylinder slot, and insert it back and forth so that the key can be inserted and removed smoothly. As a lubricant, you may use any oil except for the one you’re using. This will cause grease to stick to the pin spring, causing the lock not to rotate and not open.
3) Hotel door lock battery pack maintenance:
If the hotel door lock’s battery voltage falls below 4.7V, an alarm will sound, and the battery will need to be replaced. The battery should be replaced every 18 months.
4) Hotel door lock mainboard and lock tenon maintenance:
Mainboard and lock tenon maintenance is the most important part of RFID hotel door lock maintenance. When you find that the door lock has been closed, press the handle firmly and the door will open again. At this time, the lock tenon needs to be replaced.
It is recommended to replace the lock tenon of the same model from the original factory, and directly replace it without adjusting the lock clock. In the second renovation of the hotel, you can also consider replacing the RFID hotel door lock motherboard.
5) Always check the matching gap between the hotel door lock mortise and the lock strike.
Check whether the height of the locking bolt and the locking hole is suitable for long-term use. The best gap between the door and the door frame is 1.5 mm-3.5 mm. If there is any change, adjust the flocking hinge positioning hinge or the lock plate on the door.
At the same time, pay attention to the weather caused by cold contraction and thermal expansion (winter and spring wet, dry), to ensure that the gap between the door and the door frame, mortise lock, and lock strike plate is reasonable, and the lock is used smoothly.
6) The installation and operation of the hotel RFID lock must be correct.
When installing a hotel RFID lock, the handle and panel cannot be pasted with paper or tape. Do not install a lock when the paint on the door is wet. It is strictly forbidden to contact the lock surface with corrosive substances, damage the protective layer of the lock surface, and affect the gloss of the lock surface.
7) Use special door lock maintenance fluid to wipe spots
Some zinc alloy and copper hotel RFID locks will find “spots” after being installed on the door for a long time during use. This phenomenon is not rust but oxidation. If this happens, you can spray the door lock maintenance fluid to remove the spots.
8) It is important not to use a damp cloth to wipe the panel and handle of the door lock.
It is recommended to use RFID hotel door lock system maintenance fluid to remove surface dirt, make the surface of the door lock smooth and moist, form a protective effect on the surface, improve the continuity of surface cleanliness, and make the surface clean as new!
9) Hotel RFID door locks should be properly kept during decoration.
During the renovation period, please do not play with the locked door bolt for a long time. If you close the door after playing with the lock bolt, it is easy to damage the lock bolt!
10) The mechanical key lock of a hotel is tested
After the hotel door lock system is installed, please test it with a mechanical key. Normal operation of the door is possible.
11) Keep the motherboard and the keyhole not wet.
The mainboard and the lock tenon of the hotel card lock should not be exposed to rain, because the fine structure will cause rigidity or damage.
12) The door buckle plate must be installed in the correct position, and the locking tongue cannot be pressed down.
Otherwise, the door lock will “di…di…” alarm.
13) The hotel card lock should be powered by alkaline batteries.
Obviously, even a low battery leak can damage the smart hotel lock. It is recommended to use alkaline dry batteries (expensive, large capacity, not easy to leak), do not use dry carbon batteries (cheap, low power, easy to spread).
14) Replace the hotel key card lock battery in time.
After the low battery alarm, please replace the hotel card lock battery immediately to ensure the normal use of the door lock.
15) Use a new hotel lock battery.
Please note that no matter how many batteries are in your battery box, be sure to replace all batteries with new ones, and you cannot use old and new batteries together.
16) The mechanical key must be kept properly.
17) Regularly (every two months) “attendance cards” are issued to maintain the hotel’s key card locks.
18) The hotel door lock System operators must regularly back up the hotel card lock system database to ensure its security.
19) When decorating a hotel room, can the exposed parts of the hotel door locks, handles, panels, etc. be sealed with plastic bags?
The hotel door lock system will corrode if it is exposed to acid or alkaline substances, and blistering will cause it to delaminate. Affect the appearance quality of electronic door locks.